Range: 

  Floor Standing Wall Mounted Floor/Ceiling Dual Type Ceiling Mounted Cassette Ceiling Mounted
Built-In
Ceiling Suspended Duct Connect

Reverse Cycle (heating & cooling)

FVXS25K FVXS35K
FVXS50K
 

FTXS20K
FTXS25K
FTXS35K
FTXS50KA
FTXS60KA
FTXS71KA

FLXS25B FLXS35G
FLXS50G FLXS60G

FFQ25B FFQ35B FCQ35B FFQ50B FCQ50B FFQ60B FCQ60B FCQ71B

FBQ60B FBQ71B FHQ35B FHQ50B FHQ60B

CDXS25E FDXS25C CDXS35E FDXS35C FDXS50C FDXS60C

DC INVERTER.ai

Info

 

Power-Airflow Dual Flaps

           
 

Wide-Angle Louvres

       
 

Vertical Auto-Swing
(up and down)

     
 

Horizontal Auto-Swing
(left and right)

           
 

3-D Airflow Info3-D Airflow. Combines vertical and horizontal auto-swing to circulate cool/warm air to the corners of large spaces.

           
 

Comfortable Mode InfoComfortable Mode. The new flap changes the delivery angle to horizontal for cooling and vertical for heating operation, to prevent cold or warm air from blowing directly onto your body.

           
 

Indoor Unit Quiet Operation InfoIndoor Unit Quiet Operation Function. Sound levels are reduced by 2-3 decibels (dB) from the low fan speed for quieter heating and cooling.**

     
 

Intelligent Eye InfoIntelligent Eye. This is an infrared motion sensor with the ability to sense movement in the room. When you are in the room, the heat pump operates normally. If you leave the room for more than 20 minutes the heat pump automatically changes to an energy-saving operation.

           
 

Automatic Operation InfoAutomatic Operation (reverse cycle only). For year-round comfort, this function allows the unit to automatically switch between heating and cooling modes as required.

✓* ✓* ✓* ✓* ✓* ✓* ✓*
 

Program Dry Function InfoProgram Dry Function. This function automatically reduces the level of humidity in the room.

 

Auto Fan Speed InfoAuto Fan Speed. To reduce operating noise, the fan speed is automatically controlled by the micro-processor to suit the thermostat setting and prevailing room temperature.

     
 

Hot Start InfoHot Start. Cold air drafts are not discharged when heating operation starts or when switching to heat after defrosting.

✓* ✓* ✓* ✓* ✓* ✓* ✓*
 

Titanium Apatite Deodorising / Air-Purifying Filter InfoAir-Purifying Filter. Traps microscopic particles and decomposes odours to purify the air in your room.

         
 

Wipe Clean InfoWipe-Clean. Flat panel models can be cleaned with a single pass of a cloth.  The flat panel can also be easily removed for more thorough cleaning.

         
 

Econo Mode InfoEcono Mode. Controls the upper limit of frequency, reducing power consumption.  This reduces the load on the electrical circuit when multiple electrical devices are used simultaneously.**

       
 

Powerful Operation
(Inverter & Non Inverter) InfoEcono Mode. Pushing the POWERFUL button on the remote control gives you a boost in cooling and heating power for a 20-minute period, even if the unit is already operating at high capacity.

     
 

Indoor Unit On/Off Switch InfoIndoor Unit On/Off Switch. The unit can be started manually in the event the wireless remote controller is misplaced.

     
 

24-Hour On/Off Timer Info24-Hour On/Off Timer. The timer can be preset to start and stop the heat pump at any time within a 24‑hour period.  Once the times are set, the heat pump can be operated for a period by simply pressing the ON or OFF timer buttons.

     
 

Weekly Timer InfoWeekly Timer. This function makes it easy to enter up to four settings per day for each day of the week.  It not only allows you to program on and off time, but also the desired temperature.

         
 

Night Set Mode InfoNight Set Mode. Through the use of the ‘Timer-OFF Circuit’, the preset room temperature gently rises in cooling or falls in heating before the unit stops.  This energy efficient feature allows you to sleep comfortably without feeling a sudden change in the room temperature.

     
 

Auto-Restart after Power Failure InfoAuto-Restart. In the event that a problem develops with the unit, malfunction codes can be displayed on the liquid crystal panel of the remote control for fast and easy fault diagnosis.

 

Self-Diagnosis with Digital Display InfoSelf-Diagnosis. In the event that a problem develops with the unit, malfunction codes can be displayed on the liquid crystal panel of the remote control for fast and easy fault diagnosis.

*Reverse Cycle only (Heating and Cooling)
** Capacity may decrease when selected

Controller: 

Backlit Wireless Remote Controller (FTXS and FTKS range)

This remote controller with backlit liquid crystal display and luminescent control button, also features a built-in weekly time clock that can be programmed on or off to suit your personal lifestyle with up to four actions per day of the week.  This advanced controller not only allows you to program on/off time, but also the desired temperature. Futhermore, the copy function enables any daily program to be replicated on any other day or days as required.

Other functions include:

  • 24 hour timer
  • Weekly timer
  • Night set mode
  • Self diagnosis with digital display
  • Comfortable mode
  • Econo mode

Wireless Remote Controller (CDKS, CDXS, FLXS and FDXS range)

This easy to operate remote controller puts superior comfort at your fingertips allowing individual control of settings such as temperature, airflow volume and operation duration.

Other functions include:

  • 24 hour timer
  • Night set mode
  • Self diagnosis with digital display
  • Program dry function

Wireless Remote Controller (FVXS range)

This stylish remote controller with backlit display is easy to operate and allows you to programme on and off times as well as desired temperature during those times.

Other functions include:

  • 24 hour timer
  • Weekly timer
  • Self diagnosis with digital display
  • Night set mode
  • Auto fan speed

Wall Remote Controller (FCQ, FFQ, FBQ, FHQ range)

This remote controller is easy to operate and has a clear, large digital display for easy operation.

Other functions include:

  • Filter cleaning indicator
  • 72 hour on/off timer
  • Self diagnosis with digital display
  • Automatic operation

 

 

 

Tech Specs: 

Outdoor Unit
Single Phase

    Reverse Cycle (Heating & Cooling)
OUTDOOR UNIT   RMXS112LV1A RMXS140LV1A RMXS160LV1A
Power Supply   1 phase, 220-240 V, 50 Hz
Capacity (Rated) Cool (kW) 11.2 14.0 15.5
Heat (kW) 12.5 16.0 17.5
Total Indoor Unit Capacity kW 5.5 to 14.5 7.0 to 18.2 8.0 to 20.8
Number of Indoor Units to be Connected   6 8 9
Number of BP to be Connected   3
Casing Colour   Ivory White
Compressor Type Hermetically sealed scroll type
Motor Output (kW) 2.5  3.0 3.5
Airflow Rate (H) Cooling l/s (cfm) 1,767 (3742)
Heating l/s (cfm) 1,767 (3742)
Refrigerant Type R410A
Charge (kg) 4.0
Refrigerant Oil Model DAPHNE FVC68D
Charge (l) 1.7
Sound Level Cooling dB (A) 52 53 54
Heating dB (A) 54 55 56
Sound Power Level Cooling dB (A) 65 66 67
Heating dB (A) 67 68 69
Dimensions (HxWxD) mm  1345x900x320
Machine Weight kg  125
Operating Range Cooling °CDB -5 to 46
Heating °CWB -15 to 15.5
Number of Wiring Connections   3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP)
Piping Connections Liquid (Flared) mm 9.5
Gas (Brazed) mm 19.1
Max Interunit Piping Length Total Main Piping and Brand Piping 115 135 145
Total Main Piping 55
Total Branch Piping 60 80 90
Max Length for Each Room 15
Max Height Difference m Between indoor or BP unit and outdoor unit: 30
m Between indoor and BP unit: 15
*Necessity of additional charge = necessary. Refrigerant charge is required. (Chargeless piping length 0m).

Indoor Units 
Wall Mounted

 WALL MOUNTED   Reverse Cycle (Heating & Cooling)
OUTDOOR UNIT   FTXS20KVMA FTXS25KVMA FTXS35KVMA FTXS50KAVMA FTXS60KAVMA FTXS71KAVMA
Power Supply   1 phase, 220-240 V/220-230 V, 50/60 Hz
Front Panel Colour    White
Airflow Rate (H) Cooling l/s (cfm) 161 (343) 161 (343) 188 (399) 245 (519) 270 (572) 290 (614)
Heating l/s (cfm) 175 (371) 175 (371) 191 (406) 270 (572) 290 (614) 358 (759)
Sound Level (H/L/SL) Cooling dB (A) 38/25/22 38/25/22 42/26/23 44/35/32 45/36/33 46/37/34
Heating dB (A) 39/28/25 39/28/25 42/29/26 42/33/30 44/35/32 46/37/34
Sound Power Level (H) Cooling dB (A) 54 54 58 60 61 62
Heating dB (A) 55 55 58 58 60 62
Fan Speed   5 steps, quiet and automatic
Temperature Control   Microcomputer control
Dimensions (HxWxD) mm  295x800x215  290x1,050x250
Machine Weight kg  9 9 10 12 12 12
Piping Connections Liquid (Flared) mm 6.4
Gas (Flared) mm 9.5 12.7 12.7 15.9
Drain mm I.D. 14 / O.D. 18 18
Heat Insulation   Both liquid and gas pipes
 WALL MOUNTED   Cooling Only
OUTDOOR UNIT   FTKS20KVMA FTKS25KVMA FTKS35KVMA FTKS50KAVMA FTKS60KAVMA FTKS71KAVMA
Power Supply   1 phase, 220-240 V/220-230 V, 50/60 Hz
Front Panel Colour    White
Airflow Rate (H) Cooling l/s (cfm) 161 (343) 161 (343) 188 (399) 245 (519) 270 (572) 290 (614)
Sound Level (H/L/SL) Cooling dB (A) 38/25/22 38/25/22 42/26/23 44/35/32 45/36/33 46/37/34
Sound Power Level (H) Cooling dB (A) 54 54 58 60 61 62
Fan Speed   5 steps, quiet and automatic
Temperature Control   Microcomputer control
Dimensions (HxWxD) mm  295x800x215 290x1,050x250
Machine Weight kg  9 9 10 12 12 12
Piping Connections Liquid (Flared) mm 6.4
Gas (Flared) mm 9.5 12.7 12.7 15.9
Drain mm I.D. 14 / O.D. 18 18
Heat Insulation   Both liquid and gas pipes

Indoor Units 
Floor & Ceiling

    Reverse Cycle (Heating & Cooling)
    FLOOR STANDING FLOOR/CEILING
OUTDOOR UNIT   FVXS25KV1A FVXS35KV1A FVXS50KV1A FLXS25BVMA FLXS35GVMA FLXS50GVMA FLXS60GVMA
Power Supply   1 phase, 220-240 V/220-230 V, 50/60 Hz
Front Panel Colour   White Almond White
Airflow Rate (H) Cooling l/s (cfm) 137 (290) 142 (300) 178 (378) 126 (268) 143 (304) 190 (402) 200 (424)
Heating l/s (cfm) 147 (311) 157 (332) 197 (417) 153 (325) 163 (346) 202 (427) 213 (452)
Sound Level (H/L/SL) Cooling dB (A) 38/26/23 39/27/24 44/36/32 37/31/28 38/32/29 47/39/36 48/41/39
Heating dB (A) 38/26/23 39/27/24 45/36/32 37/31/29 39/33/30 46/35/33 47/37/34
Sound Power Level (H) Cooling dB (A) 47 48 53 53 54 63 64
Heating dB (A) 47 48 54 53 55 62 63
Fan Speed   5 steps, quiet and automatic
Temperature Control   Microcomputer control
Dimensions (HxWxD) mm  600x700x210  490x1,050x200
Machine Weight kg  14  16 17
Piping Connections Liquid (Flared) mm 6.4
Gas (Flared) mm 9.5 9.5 12.7 9.5 9.5 12.7 12.7
Drain mm 20.0 18.0
Heat Insulation   Both liquid and gas pipes

Indoor Units 
Duct-Connected

    Reverse Cycle (Heating & Cooling)
OUTDOOR UNIT   CDXS25EAVMA CDXS35EAVMA FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS60CVMA
Power Supply   1 phase, 220-240 V/220-230 V, 50/60 Hz
Airflow Rate (H) Cooling l/s (cfm)  145 (307) 158 (335) 167 (353) 200 (424) 267 (565)
Heating l/s (cfm) 145 (307) 158 (335) 167 (353) 200 (424) 267 (565)
Sound Level (H/L/SL) Cooling dB (A) 35/31/29 37/33/31 38/34/32
Heating dB (A) 35/31/29 37/33/31 38/34/32
Sound Power Level (H) Cooling dB (A)  53 55 56
Heating dB (A)  53 55 56
Fan Speed   5 steps, quiet and automatic
Temperature Control   Microcomputer control
Dimensions (HxWxD) mm   200x700x620 200x900x620 200x1,100x620
Machine Weight kg   21 25 25 27 30
Piping Connections Liquid (Flared) mm  6.4
Gas (Flared) mm  9.5 12.7
Drain mm  VP 20   I.D. 20 E.D.26
Heat Insulation   Both liquid and gas pipes
External Static Pressure Pa 30 40

Indoor Units
Ceiling Mounted Cassette

    Reverse Cycle (Heating & Cooling)
OUTDOOR UNIT   FCQ35BVE FCQ50BVE FCQ60BVE FCQ71BVE
Power Supply   1 phase, 220-240 V/220-230 V, 50/60 Hz
Airflow Rate (H) Cooling l/s (cfm)  233 (494) 250 (530) 317 (671) 317 (671)
Heating l/s (cfm) 233 (494) 250 (530) 317 (671) 317 (671)
Sound Level (H/L/SL) Cooling dB (A) 33/29 33/29 35/30 35/30
Heating dB (A) 33/29 33/29 35/30 35/30
Sound Power Level (H) Cooling dB (A) 48 48 50 50
Heating dB (A) 48 48 50 50
Fan Speed   2 steps
Temperature Control   Microcomputer control
Dimensions (HxWxD) mm  230x840x840
Machine Weight kg  24
Piping Connections Liquid (Flared) mm 6.4 6.4 6.4 9.5
Gas (Flared) mm 9.5 12.7 12.7 15.9
Drain mm I.D. 25 O.D. 32
Heat Insulation    Both liquid and gas pipes

Compact Multi-Flow

    Reverse Cycle (Heating & Cooling)
OUTDOOR UNIT   FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B
Power Supply   1 phase, 220-240 V/220-230 V, 50/60 Hz
Airflow Rate (H) Cooling l/s (cfm) 150 (318) 167 (353) 200 (424) 250 (530)
Heating l/s (cfm) 150 (318) 167 (353) 200 (424) 250 (530)
Sound Level (H/L/SL) Cooling dB (A) 30/25 32/25 36/27 41/32
Heating dB (A) 30/25 32/25 36/27 41/32
Sound Power Level (H) Cooling dB (A) 47 49 53 58
Heating dB (A) 47 49 53 58
Fan Speed   2 steps
Temperature Control   Microcomputer control
Dimensions (HxWxD) mm  286x575x575
Machine Weight kg  17.5
Piping Connections Liquid (Flared) mm 6.4
Gas (Flared) mm 9.5 12.7
Drain mm I.D. 20 O.D. 32
Heat Insulation    Both liquid and gas pipes

Indoor Units
Ceiling Mounted Built-in

    Reverse Cycle (Heating & Cooling)
OUTDOOR UNIT   FBQ60BV1 FBQ71BV1
Power Supply   1 phase, 220-240 V 50 Hz
Airflow Rate (H) Cooling l/s (cfm) 283 (600) 317 (670)
Heating l/s (cfm) 283 (600) 317 (670)
Sound Level (H/L) Cooling dB (A) 41/35 41/35
Heating dB (A) 41/35 41/35
Sound Power Level (H) Cooling dB (A) 60 60
Heating dB (A) 60 60
Fan Speed   2 steps
Temperature Control   Microcomputer control
Dimensions (HxWxD) mm  300x1,000x800
Machine Weight kg  41 41
Piping Connections Liquid (Flared) mm 6.4 9.5
Gas (Flared) mm 12.7 15.9
Drain mm I.D. 25 O.D. 32
Heat Insulation    Both liquid and gas pipes

Indoor Units
Ceiling Suspended

    Reverse Cycle (Heating & Cooling)
OUTDOOR UNIT   FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B
Power Supply   1 phase, 220-240 V 50 Hz
Front Panel Colour   White
Airflow Rate (H) Cooling l/s (cfm) 217 (458) 217 (458) 283 (600)
Heating l/s (cfm) 217 (458) 217 (458) 267 (564)
Sound Level (H/L) Cooling dB (A) 37/32 38/33 39/33
Heating dB (A) 37/32 38/33 39/33
Sound Power Level (H) Cooling dB (A) 53/48 54/49 55/49
Heating dB (A) 53/48 54/49 55/49
Fan Speed   2 steps
Temperature Control   Microcomputer control
Dimensions (HxWxD) mm  195x960x680 195x960x680 195x1,160x680
Machine Weight kg  24 25 27
Piping Connections Liquid (Flared) mm 6.4
Gas (Flared) mm 9.5 12.7 12.7
Drain mm VP 20 (External Dia. 26/Internal Dia. 20)
Heat Insulation    Both liquid and gas pipes

Product Brochure: 

Daikin Super Multi Plus Brochure New Zealand

Download Brochure

 
 
Download Adobe ReaderYou need the program Adobe Acrobat or Adobe Acrobat Reader to open the documents. The program Adobe Acrobat Reader is a freeware program and can be downloaded from www.adobe.com

 

Product Support: